Metal cassette ceilings
Metal cassette ceiling in Yerevan
600×600 mm metal cassettes on a T24 grid — a ceiling that is moisture-proof, washable, non-combustible and never sags. Any cassette lifts out for access. The Line, K45 or K90 edge defines the joint.
- Price
- from AMD 5,000/m²
- Edge
- Line, K45, K90
- Moisture resistance
- 100%

About the system
Lay-in cassettes simply sit in the cells of a T24 grid. Edges: Line — flush with the grid, K45 — 45° step, K90 — 90° step. A stepped edge drops the cassette below the grid for a deeper look.
Plain or perforated: Ø 1.8 mm perforation with acoustic fleece reduces echo in offices, schools and waiting areas. For a fully concealed grid choose Clip-in.
- Fire rating: non-combustible, KM1.
- 100% moisture resistant.
- Washable surface.
- Only 0.97 kg/m².
Price — from AMD 5,000 per m².
Specifications
| Material | aluminium 0.3–0.5 mm or galvanized steel 0.3–0.4 mm |
| Cassette thickness | 0.32 mm (standard) |
| Size | 600×600 mm |
| Edge | Line, K45, K90 |
| Grid | exposed T24 |
| Weight | 0.97 kg/m² |
| Fire | non-combustible, KM1 |
| Perforation | Ø 1.8 mm optional |
| Colours | matt white RAL 9003, silver metallic RAL 9006, matt metallic RAL 9006, graphite RAL 7024, black RAL 9005; any RAL to order |
Consumption per 1 m²
| Component | Consumption |
|---|---|
| Cassette 600×600 | 2.78 pcs |
| T24 3.6 m | 0.84 lm |
| T24 1.2 m | 1.67 lm |
| T24 0.6 m | 0.84 lm |
| Hanger | 0.7 pcs |
| Edge angle PL / PLL | perimeter |
Add 5%.
Packing
| Cassette | Pcs per pack | Pcs per block | Pack weight, kg |
|---|---|---|---|
| Line | 36 | 864 | 11.2 |
| K45 | 40 | 1,200 | 12.5 |
| K90 | 40 | 1,200 | 12.5 |
T24 grid: layout 1
Edges and perforation


Installation

- Prepare the ceiling void: fix all services so that nothing rests on the suspended ceiling grid.
- Draw a room plan and a ceiling layout before installation so that the ceiling is symmetrical to the walls and the cut modules at the edges are equal.
- Mark a level line around the perimeter (height as per design) and fix the wall angle at max 350 mm centres. The angle level sets the ceiling height. Mitre the angle at 45° in corners; on straight runs butt-joint it and fix each end. Cut with metal snips. Also fix the angle to columns and other elements the ceiling abuts.
- Install the T24 grid: mains on hangers at max 1200 mm (first max 300 mm from the wall), cross tees 1.2 and 0.6 m.
- Level the grid to the wall angle.
- Lay the cassettes wearing gloves; cut edge cassettes with metal snips.
FAQ
How much is a cassette ceiling per m²?
From AMD 5,000 per m², depending on edge, material, perforation and colour.
Can cassettes go on an existing Armstrong grid?
Yes, 600×600 lay-in cassettes fit a standard T24 grid.
We will price your project
Send us the area or a drawing — we will prepare a bill of materials with a 5% allowance and a quote per m² and per project.
- Phones
- +374 99 706 607 · +374 77 776 516
- garm.group.am@gmail.com
- Address
- 60/3 Komitas Ave, Yerevan · Mon–Fri 10:00–18:00